Choosing the Correct Pump

Fluid HandlingWPI carries a wide variety of fluid handling tools utilizing different technologies:

  • Microinjectors
  • Peristaltic pumps
  • Syringe pumps
  • Pneumatic injectors
PeriStarProPeriStarPro
AL-2000AL-2000
PV820PV820
MICRO-EPUMPMICRO-EPUMP

The range of applications and the criteria used to select a particular pump or injector is broad and complex, and we encourage you to call us at (866) 606-1974 or email customerservice@wpiinc.com and speak with an application specialist. In the meantime, here is a listing of our popular pumps and injectors sorted by technology, flow range and special features.

Special features tell you about applications or functionsof the pump. Many of the syringe pumps can be had with an alarm option that alerts you to the end of travel or blocked flow. The onew with the “P” option allow for programmable flow and volume profiles without using the RS232 computer interface.

Frequently used terms:

  • Infuse/Withdraw (I/W): Describes a feature of a syringe pump whereby the syringe plunger is held by the pusher so the motor can pull the plunger back, withdrawing fluid, as well as pushing the plunger to infuse it. 
  • Push/Pull: A feature of syringe pumps which use two syringes mounted back to back so movement of the pusher block will simultaneously withdraw fluid into one syringe and infuse an equal amount from the other.
  • RS232: This is a serial interface. Some pumps in the WPI line can be controlled by computer. Simple programs can be created to control the pump rate, the overall volume. Flow ramps or other profiles and temporal sequences can be written. In addition, pumps can be daisy-chained together to create a pump network. In such a network, each pump has its own address and can be controlled separately by the program.
Order codePump TypeFluid RangeNumber of ChannelsSpecial Features
MICRO-ePUMPMicroinjectorInjected volumes from 1pL to nanoliters1Injection pressure and holding pressure, integrated Pinpoint Cell Penetrator technology, and integrated pressure source
μPUMPMicroinjectorInjected volumes from 1pL to nanoliters1Injection pressure and holding pressure, integrated pressure source
PV850 MicroinjectorInjected volumes from 1pL to nanoliters1Injection pressure and holding pressure, requires external pressure source
Peripro-2HS Peristaltic3.5-280mL/min with supplied #17 tubing2Calibrated output Replaceable tubing cartridges
Peripro-4HS Peristaltic3.5-280mL/min with supplied #17 tubing4Calibrated output Replaceable tubing cartridges
Peripro-4LS Peristaltic0.2-18mL/min with supplied #14 tubing4Calibrated output Replaceable tubing cartridges
Peripro-8LS Peristaltic0.2-18mL/min with supplied #14 tubing8Calibrated output Replaceable tubing cartridges
MINISTAR Peristaltic0.06-2.6mL/min with 1mm tubing
0.35-14mL/min with 2.4mm tubing
1Compact design, Remote control
AL-1000 Syringe0.000073-1699mL/hr1Push/pull
AL-2000 Syringe0.000073-1699mL/hr2Push/pull (2 networked pumps)
SP100i Syringe0.0001-519mL/hr1Basic 1 Channel
SP101i Syringe0.001µL/hr – 35mL/min2Micro Dialysis application
SP200i Syringe0.001µL/hr - 145mL/min2RS232 TTL/Footswitch
SP220i Syringe0.001µL/hr - 21mL/min10RS232 Infuse Only
SP250i Syringe0.001µL/hr - 21mL/min4RS232 Infuse Only
SP210iw Syringe0.001µL/hr - 145mL/min2RS232 Infuse/Withdraw
SP230iw Syringe0.001µL/hr - 21mL/min10RS232 Infuse/Withdraw
SP120p Syringe0.1 µL/hr – 127mL/hr1+1push pull, single cycle
SP260p Syringe0.001µL/hr - 86mL/min2+2RS232 push pull, single cycle
SP210c Syringe0.001µL/hr - 86mL/min2+2RS232 push pull, continuous
UMP3TSyringe0.03nL/min - 10µL/sec1Ultra Micro Infuse/Withdraw RS232
NANOLITER2020 SyringeBolus, 2.3-69nL/Injection1Oocyte Injector, Infuse only
MMP SyringeManual 100 µL-1mL syringe1Manual
DMP SyringeManual 100 µL-1mL syringe1Digital readout Micrometer
PV830PneumaticpL to nL1Injection pressure, holding pressure and vacuum

See Selection