Choosing a Temperature Probe
  • Flexible Teflon microprobes are used for implantation in tissue, in spectrophotometer cuvettes, rectally in neonatal mice, in water baths, PCR thermal cyclers, etc.
  • Animal rectal temperatures during surgical procedures and pyrogen testing.
  • Skin temperature measurement during exercise physiology studies.

When precise temperature measurements are required, WPI can provide you with a very accurate monitor and thermocouple microprobes. WPI monitors have both resolution and accuracy of 0.1°C in the 0-50°C range and are traceable to NIST standards, whereas, other competitive electronic thermometers have an accuracy that is usually to 0.5°C or worse. Furthermore, all our type T clinical probes are guaranteed accurate to 0.1°C, due to our stringent wire standards. These are five times more accurate than competitive probes made with regular “Special Limits” wire.

Probe Sterilization Methods:

The needle microprobes and animal rectal probes are all designed to withstand sterilization by ETO gas and gluteraldehyde solution.  Our flexible implantable microprobes are both ETO gas sterilizable and autoclavable.

MT series
IT series
 RET series
HT series
BT-1


NEEDLE MICROPROBES

Fast-response needle probes for instant readings in tissue, semisolids, liquids, very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. 

NEEDLE MICROPROBES

ORDER CODESIZESTYLETIME CONSTANTISOLATEDMAX TEMPLEAD LENGTHDESCRIPTION
MT-29/1HT29 ga/1cmA0.125 secNo200°C5 ft29 gauge approximately 0.013-in
MT-29/229 ga/2cmA0.125 secNo200°C5 ft-
MT-29/329 ga/3cmA0.125 secNo200°C5 ft-
MT-29/5 29 ga/5cmA0.125 secNo200°C5 ft-
MT-26/226 ga/2cmA0.1 secNo200°C5 ft26 gauge approximately 0.018-in
MT-26/4 26 ga/4cmA0.1 secNo200°C5 ft-
MT-26/626 ga/6cmA0.1 secNo200°C5 ft-
MT-23/3 23 ga/3cmA0.15 secNo200°C5 ft23 gauge approximately 0.125-in
MT-23/5  23 ga/5cmA0.15 secNo200°C5 ft-
MT-23/823 ga/8cmA0.15 secNo200°C5 ft-
MT-4  29 ga/1cmA0.025 secNo200°C5 ftSimilar to MT-29/1 but has a blunt tip. Good for instant skin and surface temperatures, liquids
MT-D-C0.025 secNo200°C5 ftFast response surface probe (stainless steel for locating inflammation, arteries, etc. Also for dental use.

FLEXIBLE IMPLANTABLE PROBES
Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.

FLEXIBLE IMPLANTABLE PROBESFLEXIBLE IMPLANTABLE PROBES

ORDER CODESENSOR LEAD DIAMETERSTYLETIME CONSTANTISOLATEDMAX TEMPLEAD LENGTHDESCRIPTION
IT-140.050" diaD0.3 secYes150°C3 ft-
IT-180.025" diaD0.1 secYes150°C3 ft-
IT-18EXLONG 0.025” dia.D0.1 secYes150°C5 ft 
IT-21 0.016" diaD0.08 secYes150°C1 ft 
IT-230.009" diaE0.005 secYes150°C3 ftFor ultra fast measurements and for use on micro-size specimens. Tissue implantable with 239a. Needle (supplied). Rather fragile. Teflon coated.
IT-1E 0.025" diaF0.005 secYes150°C3 ftAs IT-18 sensor except bead exposed. Combines ultra- fast reponse of IT-23 with sheath strength of IT-18.
RECTAL PROBES
PROBE TYPESENSOR LEAD DIAMETERSTYLETIME CONSTANTISOLATEDMAX TEMPLEAD LENGTHDESCRIPTION
RET-2-G0.8 secNo125°C5 ftRectal probe for rats typically for fast intermittent measurements. Smooth ball tip (0.125-in. dia.) with 1" long (0.59-in. dia) stainless steel shaft.
RET-3-G0.5 secNo125°C5 ftRectal probe for mice similar to RET-2 except tip diam. 0.063-in. and shaft 3/4-in. long (0.028-in. diam.)

GENERAL PURPOSE

GENERAL PURPOSE

ORDER CODESTYLETIME CONSTANTISOLATEDMAX TEMPLEAD LENGTHDESCRIPTION
HT-1H0.5 secNo400°C5 ft“Workhorse” probe for liquids, gases, semi-solids. Plastic handle with straight stainless steel shaft. Not good for surface temperatures.
HT-2 H0.5 secNo400°C5 ftLike HT-1 except shaft length is 9-in.

 

See Selection